A V INDUSTRIAL AUTOMATION AND SERVICES
Search

Cart

More Details

KEY FEATURES

✔ Schneider Electric EasyPact CVS series
✔ Model: CVS160F
✔ Product reference: LV516342
✔ Rated current: 125A at 40°C
✔ 4-pole configuration with 3 protected poles (4P, 3D)
✔ TM-D thermal-magnetic trip unit
✔ Overload and short-circuit protection
✔ Adjustable thermal pickup from 87.5A to 125A
✔ Fixed instantaneous magnetic pickup at 1250A
✔ 36kA breaking capacity at 380/415V AC
✔ Toggle-operated mechanism
✔ Fixed backplate mounting
✔ Front-access screw terminals
✔ IP40 protection rating

TECHNICAL SPECIFICATIONS

✔ Brand: Schneider Electric
✔ Product Range: EasyPact CVS
✔ Model: CVS160F
✔ Product Reference: LV516342
✔ Product Type: Moulded Case Circuit Breaker (MCCB)
✔ Rated Current: 125A at 40°C
✔ Poles: 4P
✔ Protected Poles: 3D
✔ Trip Unit: TM-D thermal-magnetic
✔ Thermal Adjustment Range: 87.5–125A
✔ Instantaneous Magnetic Pickup: 1250A
✔ Breaking Capacity (Icu): 36kA at 380/415V AC; 70kA at 220/240V AC
✔ Frequency: 50/60Hz
✔ Impulse Withstand Voltage: 8kV
✔ Mounting: Fixed backplate
✔ Terminals: Screw connection
✔ Protection Rating: IP40
✔ Dimensions: 140 × 161 × 86mm (W × H × D)
✔ Net Weight: 1.9kg
✔ Operating Temperature: -25°C to +70°C

MODULE / COMPATIBILITY

Suitable for:

✔ Electrical distribution panels
✔ Industrial power distribution systems
✔ Commercial electrical installations
✔ Three-phase systems requiring a 4-pole breaker
✔ Applications requiring 125A-rated circuit protection, subject to system design

Installation considerations:

✔ Confirm the LV516342 reference and CVS160F frame.

✔ Check available fault current against the breaker’s breaking capacity.

✔ Verify cable sizing, terminal connections, and upstream/downstream protection coordination.

✔ Neutral protection is not provided in the specified 3D configuration

FUNCTION

✔ Protects electrical circuits against overloads
✔ Provides magnetic protection against short circuits
✔ Enables manual switching through a toggle mechanism
✔ Isolates the circuit when the breaker trips
✔ Supports electrical distribution protection in industrial and commercial panels

WORKING PRINCIPLE

  1. Current flows through the circuit breaker during normal operation.

  2. During an overload, the thermal trip mechanism responds according to its time-current characteristics.

  3. During a short circuit, the magnetic trip mechanism operates to interrupt the fault current.

  4. The breaker opens its contacts to disconnect the protected circuit.

  5. After the fault is investigated and corrected, the breaker can be reset according to the manufacturer’s instructions.

APPLICATIONS

✔ Industrial electrical distribution panels
✔ Commercial power distribution boards
✔ Three-phase electrical installations
✔ Factory and manufacturing facilities
✔ Industrial machinery supply circuits
✔ Building electrical distribution systems
✔ Feeder and distribution circuit protection

Buy Schneider EasyPact CVS160F LV516342 125A 4P MCCB online in India at the best price from A V Industrial Automation and Services.
✔ 100% genuine product
✔ Fast delivery across India
✔ Expert technical support
✔ Industrial electrical installations